46,085 research outputs found

    Minimal conductivity in graphene: interaction corrections and ultraviolet anomaly

    Get PDF
    Conductivity of a disorder-free intrinsic graphene is studied to the first order in the long-range Coulomb interaction and is found to be \sigma=\sigma_0(1+0.01 g), where 'g' is the dimensionless ("fine structure") coupling constant. The calculations are performed using three different methods: i) electron polarization function, ii) Kubo formula for the conductivity, iii) quantum transport equation. Surprisingly, these methods yield different results unless a proper ultraviolet cut-off procedure is implemented, which requires that the interaction potential in the effective Dirac Hamiltonian is cut-off at small distances (large momenta).Comment: 5 pages, 1 figure; Reply to the Comment by I.F. Herbut, V. Juricic, O. Vafek, and M.J. Case, "Comment on "Minimal conductivity in graphene: Interaction corrections and ultraviolet anomaly" by Mishchenko E. G.", arXiv:0809.0725, is added in Appendi

    Shiga Toxin Detection Methods : A Short Review

    Full text link
    The Shiga toxins comprise a family of related protein toxins secreted by certain types of bacteria. Shigella dysenteriae, some strain of Escherichia coli and other bacterias can express toxins which caused serious complication during the infection. Shiga toxin and the closely related Shiga-like toxins represent a group of very similar cytotoxins that may play an important role in diarrheal disease and hemolytic-uremic syndrome. The outbreaks caused by this toxin raised serious public health crisis and caused economic losses. These toxins have the same biologic activities and according to recent studies also share the same binding receptor, globotriosyl ceramide (Gb3). Rapid detection of food contamination is therefore relevant for the containment of food-borne pathogens. The conventional methods to detect pathogens, such as microbiological and biochemical identification are time-consuming and laborious. The immunological or nucleic acid-based techniques require extensive sample preparation and are not amenable to miniaturization for on-site detection. In the present are necessary of techniques of rapid identification, simple and sensitive which can be employed in the countryside with minimally-sophisticated instrumentation. Biosensors have shown tremendous promise to overcome these limitations and are being aggressively studied to provide rapid, reliable and sensitive detection platforms for such applications.Comment: 16 pages, 2 figure
    corecore